• 中文核心期刊
  • CSCD来源期刊
  • 中国科技核心期刊
  • CA、CABI、ZR收录期刊

Message Board

Respected readers, authors and reviewers, you can add comments to this page on any questions about the contribution, review,        editing and publication of this journal. We will give you an answer as soon as possible. Thank you for your support!

Name
E-mail
Phone
Title
Content
Verification Code
Volume 30 Issue 8
Aug.  2015
Turn off MathJax
Article Contents
LI Hai-qin, FU Guang-hua, HUANG Yu, WEI Qi-peng, TANG Wei-guo. Establishment and Application of Multiplex PCR Assay for Detection of H5、H9 Subtypes Avian Influenza Virus and Duck Tembusu Virus[J]. Fujian Journal of Agricultural Sciences, 2015, 30(8): 727-730. doi: 10.19303/j.issn.1008-0384.2015.08.001
Citation: LI Hai-qin, FU Guang-hua, HUANG Yu, WEI Qi-peng, TANG Wei-guo. Establishment and Application of Multiplex PCR Assay for Detection of H5、H9 Subtypes Avian Influenza Virus and Duck Tembusu Virus[J]. Fujian Journal of Agricultural Sciences, 2015, 30(8): 727-730. doi: 10.19303/j.issn.1008-0384.2015.08.001

Establishment and Application of Multiplex PCR Assay for Detection of H5、H9 Subtypes Avian Influenza Virus and Duck Tembusu Virus

doi: 10.19303/j.issn.1008-0384.2015.08.001
  • Received Date: 2015-06-19
  • Publish Date: 2015-08-18
  • The aim of this study is to establish a rapid multiplex PCR assay for detection of H5,H9 subtype avian influenza virus(AIV)and duck Tembusu virus(DTMUV).According to the HA gene sequences of H5 and H9AIV and NS5 gene of DTMUV in GenBank,three primer sets specific to these three kinds of viruses were designed,respectively.The multiplex PCR for simultaneous detection of AIV(H5,H9)and DTMUV was established,and was applied to clinical testing for three kinds of viruses.The specificity and sensitivity of the multiplex PCR were tested.The results showed that the assay could specifically amplify the gene fragments of H5AIV(380bp),H9 AIV(732bp),and DTMUV(250bp),and were all negative for detection of other duck viruses.This method showed a sensitive of 533pg·μL-1 for H5 AIV,56pg·μL-1 for H9,and 6.6ng·μL-1 for DTMUV.Additionally,the detection results of 200 clinical samples indicated that this multiplex PCR method proved a a rapid,sensitive and specific tool for clinical samples detection.
  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (125) PDF downloads(0) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return